That ur fan stays on even when no load is plugged to the system is a put off for me... just like @Dam5reey and someone on this thread reviewed Bread 1.5kva and Haisic 1.5kva inverters, I deduced that Bread was way better in Comparison to d Haisic bkuranga: |
![]() |
swagifted: Let the man wey just return from Obodoyinbo be na Senior man.... ![]() ![]() 6 Likes |
![]() |
ManAdii: Elaborate boss, I wanna learn sir |
![]() |
QuoteJust1nce: The price between Panasonic n LG is wide, does the huge price difference really worth it in all overall system performance... please help share d manual boss |
![]() |
Gurus in the house, which is better in effective cooling system between Panasonic air conditioner and LG air conditioner and which is better in energy efficiency between d two of d same capacity
|
![]() |
7 Likes |
![]() |
dryakson: What's ur load profile |
![]() |
Compliant: No, 1hp is approximately 750watt plus additional 150watt, making a total of 900watt multiply by 12hours, making 10800watthour. So ur best bet is a 15kwh battery, at full charge, it will suit ur need 2 Likes |
![]() |
ask4bk: He barely responds to technical questions, he's just a marketer/business man doing his business 1 Like |
![]() |
HeavenlyBang: Canadian don't produce lower wattage s, I'm pretty sure that it's those relabelled, repackaged Alaba type that the true capacity of the said 250watt might even be 175watt 3 Likes |
![]() |
jasp12: It is utmost impossible to have 100% harvest from ur s, max is always 70%. So going by that u can series 19pcs n discard d remaining 6. |
![]() |
jasp12: What is VOC of the 250watt ? 1 Like |
![]() |
Sakopower: When one of ur teams was asked about the best way to protect sako inverters from lightning/thunder strike since it interferes with dish signal amidst other problem if connected to an earth rod, the responded that lightning/thunder strike is a natural phenomenon n can't be prevented. I was just dumbfounded with his reply, like mehn, people dey this world oooo there are engineers n there are enginaira |
![]() |
HeavenlyBang: I don't believe that bro, I use 5.888kwh lfp battery with a Bluetooth enabled bms, the day i tried my 2.2kw electric kettle on d 3.3kw srne inverter while I was also monitoring the battery behaviour on my phone, I'm happy to tell u that the inverter shut down on d basis of an overload while on the bms app, there wasn't any warning sign |
![]() |
HeavenlyBang: I saw ur post where u loaded ur 3.3kw SRNE inverter to 2.6kw, my brother you enjoyed that privilege cos ur solar harvest is ing the load with d major input else, that 3.3kw inverter can not perform at such level... it's something have tried bro, I also use 3.3kw high frequency inverter |
![]() |
loluskysat: Outside using an oscilloscope to affirm this, the humming sound at lightning points was not noticed and standing fan runs smoothly so I don't think u are right on this one boss |
![]() |
ManAdii: Dey play!!! Abi no be 5years warranty Sako gave on their lithium battery pack that a colleague here is suffering n battling with an impaired one few months after purchase |
![]() |
compunigeria: My brother, have been battling same issue in one of installations, I was dumbfounded listening to those problems u shared from my client cos i never had or seen such scenario before until I visited the site n saw things myself, what I discovered was that the sako inverter interference n d other problems u shared above are due to the fact that u connected the inverter to d earth... I ed their n the person said I should connect only the s to the earth n when I further asked him that how do I protect the inverter from lightening through d grid, he responded that such is a natural disaster n can't be prevented ![]() ![]() 4 Likes |
![]() |
adewasco2k: Yes u need to change the inverter to a higher capacity but in addition to that, u need to also look into the MCB u used, current close to 100h ing through it might also result in rise in temperature of the equipment |
![]() |
HeavenlyBang: Yeah, there product is cheap but then in renewable energy every other factors matters too 1 Like |
![]() |
HeavenlyBang: I will rather advice him to stay away from Sako n embrace a different product entirely, have had too many issues with them of late that even their couldn't proffer solution to |
![]() |
bassdow: Can u please prove this scientifically n mathematically sir, cos there's been some discussions ongoing regarding a person on this same platform that had mixed s installed n yet gietting close to 100% harvest at STC |
![]() |
skywalker95: 2.5kva Smarten, Afriipower or soccerpower inverter should be around 270k and get an external 40amps MPPT controller and you're good to go.... no law says hybrid is for lithium, so far the controller n standalone inverter are editable, then they are suitable for lithium battery installation 1 Like |
![]() |
eghos12: I would advice that u tell him to go get a 10mm cable, so that he won't push everything on ur head if the installation goes south or something awful happens in the future. Though 6mm should also suffice sha but if he wish to upgrade, then cable upgrade will be required |
![]() |
eghos12: Yeah, u will have a total of 24.9amps and use10mm cable instead |
![]() |
eghos12: Yes, it can if the 3s are wired in series instead of parallel connection, wiring d 3s in series will exceed d input voltage of the controller. |
![]() |
HeavenlyBang: Have u added more solar s to ur initial string |
![]() |
TCD: 12kw SRNE inverter has this feature u looking for, have installed one before n it's pretty cool 1 Like |
![]() |
Dam5reey1: This bros just dey play on people's intelligence here sha.... if it is 100Ah series together, then what is 12v doing in the statement? I expected to see 24v 100Ah battery, isn't it? |
![]() |
easyyoke: Use 10mm cable but if u thinking of adding more in the future, then 16mm cable is ur best bet |
![]() |
easyyoke: Before I will align with the 2s3p, first of all, what is the amperage of the controller? If it is above 50amps, then ur best bet is 2s3p otherwise u might have problem using 20, 30 or 40amps controller for d connection |